A barndominium with a walkout basement built into a sloping lot, the lower level opening onto a patio at grade, with pines behind.

Barndominium Floor Plans with Basement in Washington State

Most barndominiums sit on a slab, but a basement makes sense on a sloping lot, where a walkout lower floor comes almost free, and on the dry side, where the footing has to go below the county's frost line anyway. A basement under a steel or pole barn shell changes the building more than any other feature: the frame sits on a concrete wall instead of a slab edge or posts, the lower floor needs escape openings and dry walls, and in seven Washington counties the code adds radon-resistant construction. Decide early, because a basement is a foundation choice, not an add-on.

What actually changes with this feature

The look is the easy part. These are the decisions that follow from it.

Escape openings in the basement

Under WAC 51-51-03100, basements and every sleeping room need at least one operable emergency escape and rescue opening, and where a basement contains sleeping rooms, each of those rooms needs its own. Washington allows an exception for sleeping rooms in a sprinklered dwelling where the basement has two code exits, or one exit and one escape opening. A walkout wall makes all of this simpler; a fully buried basement needs window wells.

Window wells sized to climb out

An escape opening whose sill is below grade needs an area well with at least 9 square feet of horizontal area, at least 36 inches in projection and width, and big enough for the window to open fully, under R310.4 of the 2021 International Residential Code. Deeper wells need a ladder or steps. Washington also accepts a removable well cover that meets the code as no obstruction to the escape path.

Footing drains go anywhere but the septic

Washington's on-site sewage rule, WAC 246-272A-0230, keeps footing drains, roof drains and other non-sewage drains out of the septic system, the drainfield area and the reserve area. A basement needs its perimeter drain carried to daylight on a slope or to a separate dry well or sump, and a basement bathroom below the building sewer needs a pump to reach the tank.

West side slopes, east side frost

West of the Cascades, basements are mostly walkouts on sloping lots, and the job is keeping a wet hillside's water away from the wall with drainage, membrane and backfill. East of the Cascades, the footing already goes down to the frost depth the county sets in its Table R301.2, so the extra dig to a full basement is smaller than it looks, and most of the high-radon counties are on that side of the state.

A barndominium with a walkout basement built into a sloping lot, the lower level opening onto a patio at grade, with pines behind.
Radon is a county-by-county rule

In seven Washington counties, radon control is built in

Washington's residential code, WAC 51-51-0332, applies the radon control provisions of Appendix F to buildings constructed in high radon potential counties listed in Table AF101(1), and to any building using the unvented crawl space method. The table, in WAC 51-51-60101, lists Clark, Ferry, Okanogan, Pend Oreille, Skamania, Spokane and Stevens counties, and the appendix states that unvented crawl spaces are not permitted in any high radon potential county. A basement plan in those counties includes the sub-slab and vent-pipe details from the start, which is far cheaper than retrofitting a mitigation system later.

Common ways to build this

Three common ways to lay this out. Yours does not have to match one exactly — this is a starting point for the conversation, not a catalog.

Walkout lower floor

40' x 50' main floor / 1,400 sq ft walkout basement

The house on the main floor and a finished walkout lower level on the downhill side with two bedrooms, a bath and a family room. Every lower-floor bedroom has a full-size window or door on the walkout wall, so no area wells are needed.

Full basement under a pole barn house

36' x 48' main floor / 1,728 sq ft basement

A concrete basement wall carries the frame instead of posts in the ground. The lower floor holds mechanical, storage and a guest bedroom with an area well and an escape window, and in a high-radon county the slab has the radon details under it.

Partial basement under the living wing

2,400 sq ft slab shop and house / 900 sq ft basement under the house end

A slab under the shop and garage and a basement only under the living end, for storage, a safe room or mechanical. The step between the slab and the basement wall is a frost and drainage detail, drawn with the foundation.

Barndominium with a Basement: common questions

6 questions worth settling before this plan is drawn. If yours is not on the list, put it in the survey.

Which Washington counties require radon-resistant construction?
Table AF101(1) in WAC 51-51-60101 lists Clark, Ferry, Okanogan, Pend Oreille, Skamania, Spokane and Stevens counties as high radon potential (zone 1). WAC 51-51-0332 applies the radon control provisions to buildings in those counties, and to any building using an unvented crawl space.
Does every basement need an escape window?
Under WAC 51-51-03100, basements need at least one operable emergency escape and rescue opening, and each basement sleeping room needs its own. Exceptions include basements used only for mechanical equipment and not over 200 square feet, and sleeping rooms in a sprinklered dwelling where the basement has the exits the section describes.
How big does a window well have to be?
At least 9 square feet of horizontal area, with a projection and width of at least 36 inches, and large enough for the escape window to open fully, under R310.4 of the 2021 International Residential Code.
Can the footing drain go into my septic system?
No. WAC 246-272A-0230 requires footing drains, roof drains and other non-sewage drains to be kept out of the septic system, its drainfield and its reserve area.
Can I have an unvented crawl space instead of a basement?
Not in a high radon potential county: the appendix states that unvented crawl spaces are not permitted there. Elsewhere, an unvented crawl space brings the radon control provisions with it under WAC 51-51-0332, and a vented crawl space needs Washington's six-mil black polyethylene ground cover.
Is a basement worth it under a barndominium?
On a sloping lot, usually yes, because the walkout floor is cheap space. On a flat, wet west-side lot, often no, because keeping water out of a buried wall costs more than building the same area above grade. On the dry side, the frost-depth footing narrows the gap.

Want this drawn for your program and your parcel? That is where a build actually starts.

Sources

Code references on this page are to the 2021 International Residential Code as amended by Washington (chapter 51-51 WAC) and the 2021 Washington State Energy Code, Residential (chapter 51-11R WAC), in force since March 15, 2024. The State Building Code Council has scheduled the 2024 editions to take effect May 3, 2027; the edition your permit is reviewed under governs.

  1. Washington Administrative Code, WAC 51-51-0332, Protection against radon
  2. Washington Administrative Code, WAC 51-51-60101, Appendix AF Radon control methods
  3. Washington Administrative Code, WAC 51-51-03100, Emergency escape and rescue openings
  4. Washington Administrative Code, WAC 51-51-0408, Under-floor space
  5. Washington Administrative Code, WAC 246-272A-0230, On-site sewage design requirements
  6. ICC, 2021 International Residential Code, Chapter 3 Building Planning

Start your plans

Tell us what you want to build and we will draw this for your program, then confirm what it looks like on your parcel, which office permits it, and a realistic budget range. That conversation costs nothing.